Osburn 2000 Wood Stove with Variable Speed Blower (130 cfm)
From $2,299.00
To $8,815.00
OVERVIEW
Year after year, the 2000 model remains one of the most popular wood stoves in the Osburn range.
In 2018, Osburn redefines the design of this heating appliance and sets new standards for emissions. This new version keeps its 2.4 cubic foot combustion chamber and still offers the same power with an impressive emission performance of around 1.54 g/h. With this model, the 130 CFM fan is still included; unquestionably the best opportunity this season!
Its new cast iron door gives a youthful look with elegant lines while retaining the spirit of wood heating. Customize your appliance to suit your décor: refined door overlays, new leg designs, glass ash lip with integrated ash pan; significant innovations for the most seasoned experts..
Required to complete the wood stove:
- Door Overlay
- Pedestal/Leg Kits
Appliance Performance
Fuel type : | Dry cordwood | |
Recommended heating area-ft² : () | 500 - 2,100 | |
Overall firebox volume : | 2.4 | |
EPA loading volume-ft³ : | 2.02 | |
Maximum burn time : () | 8h | |
Maximum heat output (dry cordwood) : (2) | 75,000 BTU/h (22.0 kW) | |
Overall heat output rate < : (2) (3) | 14,800 BTU/h (4.34 kW) to 28,600 BTU/h (8.38 kW) | |
Average overall efficiency (EPA cribs/Douglas fir) : (3) | N.A. (HHV) (4) | N.A. (LHV) (5) |
Average overall efficiency (dry cordwood) : (3) | 69 % (HHV) (4) | 74 % (LHV) (5) |
Optimum efficiency : (6) (7) | 77 % | |
Average particulate emissions rate : (8) | 1.54 g/h | |
Average CO : (9) | 89.4 g/h |
(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb./ft³ and 20 lb./ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb./ft³ and 12 lb./ft³. The moisture content is between 19% and 25%.
(3) As measured per CSA B415.1-10 stack loss method.
(4) Higher Heating Value of the fuel.
(5) Lower Heating Value of the fuel.
(6) Performances based on a fuel load prescribed by the standard at 7 lb./ft³ and with a moisture content between 19% and 25%.
(7) Optimum overall efficiency at a specific burn rate (LHV).
(8) This appliance is officially tested and certified by an independent agency.
(9) Carbon monoxide.
General Features
Set Product as Sales | No |
---|---|
Set Product as Featured | No |