Description
Equipped with high-density bricks, a top heat deflector to redirect heat in front of the stove as well as side panels that reduce clearances, the Osburn 950 offers quality and performance. Enjoy your winter evenings more than ever before!
Appliance Performance
Fuel type : | Dry cordwood | |
Recommended heating area-ft² : () | 250 - 1,200 | |
Overall firebox volume : | 1.7 | |
EPA loading volume-ft³ : | 1.55 | |
Maximum burn time : (1) | 5 h | |
Maximum heat output (dry cordwood) : (2) | 45,000 BTU/h (13.19 kW) | |
Overall heat output rate < : (2) (3) | 12,124 BTU/h (3.55 kW) to 26,700 BTU/h (7.83 kW) | |
Average overall efficiency (EPA cribs/Douglas fir) : (3) | N.A. (HHV) (4) | N.A. (LHV) (5) |
Average overall efficiency (dry cordwood) : (3) | 74 % (HHV) (4) | 79 % (LHV) (5) |
Optimum efficiency : (6) (7) | 80 % | |
Optimum heat transfer efficiency(8) | 79 % | |
Average particulate emissions rate : (9) | 1.8 g/h | |
Average CO : (10) | 74 g/h |
(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time, and maximum heat output.
(*) Recommended heating area and maximum burn time may vary subject to location in the home, chimney draft, heat loss factors, climate, fuel type, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(3) As measured per CSA B415.1-10 stack loss method.
(4) Higher Heating Value of the fuel.
(5) Lower Heating Value of the fuel.
(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(7) Optimum overall efficiency at a specific burn rate (LHV).
(8) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(9) This appliance is officially tested and certified by an independent agency.
(10) Carbon monoxide.
General Features
Combustion technology | Non-catalytic |
High-efficiency certified appliance | CSA B415.1-10 |
Maximum log length | 17" |
Log positioning | Loading over depth |
Chimney diameter | 6" |
Flue outlet diameter | 6" |
Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Minimum chimney height (feet) | 12' |
Baffle type | High-quality vermiculite |
Approved for an alcove installation | Yes |
Approved for a mobile home installation | Yes, with fresh air intake |
Shipping Weight | 280 lb. (150 kg) |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface – dimensions (Width X Height) | 15 3/4" x 9 3/8" |
Glass air-wash system | Yes |
Overall dimension (Height) | 28 7/8" |
Overall dimension (Width) | 20 1/4" |
Overall dimension (Depth) | 27 7/8" |
Door opening – dimension (Height) | 7 5/8" |
Door opening - dimension (Width) | 12" |
Firebox – dimension (Height) | 11 3/4" |
Firebox – dimension (Width) | 14 1/4" |
Firebox – dimension (Depth) | 19 1/8" |
Firebox lined with refractory bricks for better heat distribution | Yes |
Stainless-steel secondary-air system improving gas combustion | Yes |
Steel thickness – body | 3/16" |
Steel thickness – top | 5/16" |
USA standard (emissions) | EPA |
Canadian Standard (emissions) | CSA B415.1-10 |
USA standard (safety) | UL 1482, UL 737 |
Canadian standard (safety) | ULC S627 |
Tested and listed as per applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | Limited lifetime |
Specifications
BTU |
45,000 BTU |
Heating Capacity |
250-1,200 sq. ft. |
Firebox Size |
1.7 cu ft. |
Log Length |
up to 18” |
Flue Pipe Diameter |
6” |
Weight |
280 lbs. |
Width |
20 1/4” |
Depth |
27 7/8” |
Height |
38 7/8” |
Mobile Home Approved |
Yes |
Options
Click to see options
130 cfm Blower with Variable Speed Control (Thermodisc Included) --- provide mechanical convection of heat to the room |
![]() |
5" Fresh Air Intake Kit for Wood Stove on Legs --- enable outside combustion air to feed into your appliance making the fireplace more efficient |
![]() |
5" Fresh Air Intake Kit for Wood Stove on Pedestal --- allows outside combustion air to be supplied to the stove |
![]() |
5" X 4' Insulated Flex Pipe for Fresh Air Intake Kit --- consists of a 4 ft. length of 5 in. diameter flexible insulated pipe, fits on fresh air kit adaptor |
![]() |
Glass Ash Lip --- keeps the stove's surrounding area clean |
![]() |
Rigid Firescreen --- enhances crackle of your fire |
![]() |
Accessories
Blowers
|
Adhesives, Gaskets, and Insulation
|
Paint
|
Maintenance Products
|
Meters
|
Fire Starters
|
Fireplace Tool Sets
|
Hearth Pads
|
Heat Shields
|
Set Product as Sales | No |
---|---|
Set Product as Featured | No |